Everest XCR - Product Manual |
Wiring and Connections
INGENIA | 08/04/2019
44
Specification
Value
Brake PWM frequency
4 kHz ~ 40 kHz
Next figure show how the typical connection of the brake using a dedicated power supply.
Next figure shows the connection with single power supply (< 50V systems). Note that it is possible to operate a 24 V
brake with a 48 V power supply by configuring the maximum PWM duty cycle of the brake to 50%. In this case
configure it carefully before physically connecting the brake.
9.4.3. External temperature sensor wiring
The Everest XCR motor safety system connector allows the connection of an external temperature sensor based on
changes of resistance (PTC thermistor, bimetal, NTC, PT100, silicon temperature sensors) to measure the motor