Everest XCR - Product Manual |
Wiring and Connections
INGENIA | 08/04/2019
48
For single-ended devices, connect the positive pins of CLK+ and DATA+ and leave the other pins unconnected.
For dual daisy-chain BISS-C use the following connection. Dual BISS-C can be used for redundancy or to read
position of the rotor before and after a gearbox.
9.5.3. Absolute Encoder 2
The Absolute Encoder 2
interface can be used as
a position, velocity and commutation feedback device. This
feedback is shared with the incremental encoder input,
so you will have to select which one is used by software.
Specification
Value
Type of inputs
Differential / Single ended
ESD protected