Chapter 1 - General description
The power supply is depending on the drive type:
XtrapulsCD1-a-230/I: 230 V
AC
single-phase mains operation power supply with limitation of the operation
power (see chapter 2, section 1.1) or three-phase via a transformer or an autotransformer or three-phase
mains operation if there are three-phase mains available in 200 to 230 V
AC
.
XtrapulsCD1-a-400/I: 400 to 480 V
AC
three-phase mains operated power supply.
A soft start system of the power supply limits the inrush current at power on.
The very small dimensions of the XtrapulsCD1-a drive allow an optimum integration in 300 mm deep cabinets
(connectors included).
The
VISUAL DRIVE SETUP
software, which is PC compliant with the WINDOWS® operating system, allows the
display and easy modification of all drive parameters. The commissioning of the drive is quick and easy thanks to
the "digitizing oscilloscope" function included in this software.
2.2 - REFERENCE TO THE STANDARDS: "CE" CERTIFICATION
Series
XtrapulsCD1-a
drives have been approved for their conformity with the EMC standards regarding the
power servos referenced in the EN 61800-3 standard concerning "electrical power servos with variable speed":
EN 55011, Group 1, C3 category regarding conducted and radiated radioelectric disturbances,
EN 61000.4-2-3-4-5 regarding immunity.
Standard to be applied to the electrical equipments of industrial machines: EN 60204.1.
2.3 - REFERENCE TO THE STANDARDS: "UL" LISTING
XtrapulsCD1-a series have been «
c
UL
us
» listed according to UL508C and UL840 regarding the insulator.
This product was evaluated to:
-
the Third Edition of UL508C, the UL Standard for Power Conversion Equipment for the UL Listing
(USL),
-
the CSA Standard for Industrial Control Equipment, C22.2 N° 14-10 for the Canadian UL Listing
(CNL).
Providing that the manual is specifying that the end user has to provide an isolated power supply, for 24 VDC
auxiliary input protected by a 4 A UL Listed fuse, the power board is considered within a limited voltage/current
circuit per section 31.4 of UL508C. Therefore, spaces on the power board are not required to be evaluated per
section 31.2 of UL508C and were evaluated according to UL 840.
Per UL 840 requirements, spaces are limited at 2.5 mm assuming pollution degree 2 environment.
Ground connection is fixed in the frame of the device by a rivet, Avibulb masse, BN10-5168. The connector
complies with standard dimensions given in table 6.2 of UL 310, the standard for Electrical Quick connect
terminals.
3 - OTHER DOCUMENTS
-
"CD1-a/CD1-k SinCos track feedback": application note regarding the use of motors equipped with
"SinCos tracks" position sensors.
-
"CD1-a/CD1-k absolute encoders feedback": application note regarding the use of absolute single-turn
multi-turn or linear encoders using the ENDAT® or HIPERFACE® Communication protocols.