43
XtrapulsCD1-a
Chapter 6 - Commissioning
- Enable the drive and check that the slave axis actually follows the displacement of the master axis with the
correct reduction ratio
.
- If the slave axis does not follow the displacement of the master axis, check the
CV0
input. It must be disabled.
- If there is a loud noise in the motor during the axis motion, set at 0 the
Feedforward acceleration
gain.
If using
a SinCos master encoder, check also that the
Pulse interpolation
command is enabled in the
Second sensor
window.
- If the motion direction is not correct, select the
Reverse position
command in the
Second sensor
window or
the
Reverse movement
" in the window "
Speed limit
".