If after switch the cables and no light is being emitted from either cable ensure the optic
amplifier is powered and on.
If problems persist reset-up the optic amplifier. (See Section 9.6)
b)
Optic Amplifier
1. If a problem is suspected with the
optic amplifier
ensure that it is properly set up. (See Section 9.6)
2. If the screen is scrambled this indicates a faulty unit. (See Section 9.6)
10.6.2
Reflective Counter Sensor
On the drive train side of the sensor a green and amber light should be
lit when properly aligned. When the beam is broken by a piece of paper
only the green light will be lit.
o
If the amber light is not displayed wipe the sensor lens and
reflective tape until it is displayed.
o
If no lights are displayed check for properly connected wires
and faulty wires.
10.6.3
Door Switch
Test the continuity, if the continuity does not correspond to the table below replace the switch.
Table 2: Door Switch Continuity
Note: Normal operation requires that wires be connected to Terminals 1 and B
10.6.4
Fold Plate Switch
Test the continuity, if the continuity does not correspond to the table below replace the switch.
1 & A
1 & B
Switch Closed
Open Continuity
Switch Open
Continuity No
Location of LED’s
Figure 25: Sensor
A
B
1
Figure 26: Door Switch
Summary of Contents for 7K Plus
Page 2: ...ii...
Page 31: ...31 11 Appendix Side Frame Assembly Drawings...
Page 33: ...33 7KPlus Exploded Drive Train...
Page 34: ...34 10 Amp IEC Bracket Assy IEC Outlet...
Page 36: ...36 Retard Assembly...
Page 37: ...37 7KPlus Schematic...
Page 38: ...38...
Page 51: ...51...
Page 52: ...52 Phone 866 427 4546 Fax 603 332 8043 www brilininc com...