XC886/888CLM
Serial Interfaces
User’s Manual
12-49
V1.3, 2010-02
Serial Interfaces, V 1.0
Note: The target of an access to CON (control bits or flags) is determined by the state of
CON.EN prior to the access; that is, writing C057
H
to CON in programming mode
(CON.EN = 0) will initialize the SSC (CON.EN was 0) and then turn it on
(CON.EN = 1). When writing to CON, ensure that reserved locations receive
zeros.
BE
3
rwh
Baud rate Error Flag
0
No error
1
More than factor 2 or 0.5 between slave’s actual
and expected baud rate
BSY
4
rh
Busy Flag
Set while a transfer is in progress
MS
6
rw
Master Select Bit
0
Slave mode. Operate on shift clock received via
SCLK.
1
Master mode. Generate shift clock and output it
via SCLK.
EN
7
rw
Enable Bit = 1
Transmission and reception enabled. Access to status
flags and Master/Slave control.
0
5
r
Reserved
Returns 0 if read; should be written with 0.
Field
Bits
Type Description
*