XC886/888CLM
Capture/Compare Unit 6
User’s Manual
14-51
V1.3, 2010-02
CCU6, V 1.0
Note: The dead-time counters are clocked with the same frequency as T12.
This structure allows symmetrical dead-time generation in center-aligned and in
edge-aligned PWM mode. A duty cycle of 50% leads to CC6x, COUT6x switched
on for: 0.5 * period - dead-time.
Note: The dead-time counters are not reset by bit T12RES, but by bit DTRES.
14.3.3
Timer 13 – Related Registers
The generation of the patterns for a single channel PWM is based on timer T13. The
registers related to timer T13 can be concurrently updated (with well-defined conditions)
in order to ensure consistency of the PWM signal. T13 can be synchronized to several
timer T12 events.
Timer T13 supports only compare mode on its compare channel CC63.
Register T13 represents the counting value of timer T13. It can only be written while the
timer T13 is stopped. Write actions while T13 is running are not taken into account.
Register T13 can always be read by software.
Timer T13 supports only edge-aligned mode (counting up).
DTRx
(x = 0, 1, 2)
6:4
rh
Dead-Time Run Indication Bits
Bits DTR0..DTR2 indicate the status of the dead-time
generation for each compare channel (0, 1, 2) of timer
T12.
0
The value of the corresponding dead-time
counter channel is 0.
1
The value of the corresponding dead-time
counter channel is not 0.
0
3, 7
r
Reserved
Returns 0 if read; should be written with 0.
T13L
Timer T13 Counter Register Low
Reset Value: 00
H
7
6
5
4
3
2
1
0
T13CVL
rwh
Field
Bits
Type Description
*