40
Figure 4.2
If your installation
excludes
fixed DC power
and excludes
the connection of an
Ethernet cable, continue below with step 1; otherwise, use the instruction set
supplied in Figure 4.3.
─
1
Mount or place RGX
If the unit has been prepared for mounting, use the customer-supplied equipment and services
to complete the mounting task; otherwise place the unit at the desired operation location.
2
Port caps and power cables
─
Next,
choose
only one
instruction set below—a or b or c—that applies to the operational power
source the RGX will use.
WARNING:
Only
one of the following power input ports is permitted to be connected at a given
time: 12V Charger Port, IS Power Port, or 9–30 VDC Terminal Block.
When installing a port cap or connecting a power supply cable to a port, push the cap or cable
slightly, then turn its swivel connector clockwise (approximately 45°) until it clicks closed or a
full-stop connection feedback is felt.
a No external power source
If the RGX will draw operational power
only
from its factory-installed battery, cap the charging
power-supply port
and
the IS power port.
Skip to Operation Precheck.
b Power supply accessory (ISERTPS or ERTPS)
WARNING:
Only
one of the following power input ports is permitted to be connected at a given
time: 12V Charger Port, IS Power Port, or 9–30 VDC Terminal Block.
If the RGX will draw operational power from a compatible power supply accessory, cap the
RGX charging power-supply port.
Ensure the ISERTPS or ERTPS is installed, connected, and used in accordance with the
instruction provided in its product manual.
Skip to Operation Precheck.
c Charging power supply (part number 17158665)— use
only
in a nonhazardous location
WARNING:
Only
one of the following power input ports is permitted to be connected at a given
time: 12V Charger Port, IS Power Port, or 9–30 VDC Terminal Block.
If the unit will be operated in a nonhazardous location and will draw operational power using
the RGX charging power supply, cap the RGX IS power port.
Uncap the unit's charging power supply port to expose the port for use; connect the power-
supply cable to the port. Plug the cord into a compatible electrical outlet.
Skip to Operation Precheck.
Figure 4.2 Installation for RGX that
excludes
fixed DC power
and excludes
Ethernet
Figure 4.3
If your installation
includes
the connection of an external power
source, an Ethernet cable, or both, continue below with step 1;
Document Number: 0000037533
DO NOT CHANGE WITHOUT THE FOLLOWING AGENCY APPROVALS(S):N/A
Modified: 2018-05-25 13:18:14 EDT
State:In Work
INDUSTRIAL SCIENTIFIC CORPORATION
Title: PRODUCT MANUAL RGX GATEWAY-EN-1
Eng:
Drawing No: 17158071-1
Drawn By: Gaygan, Nancy
Created: 2018-05-16 10:24:51 EDT
Rev: 1
Printed By: Kuzmich, Bob
Int: 1.5
Date:May 29, 2018