44
ILVFE-series
user manual
12
"Jog reverse"
Drive accelerates to A404 [Jog Frequency] according to A405 [Jog
Accel/Decel] and ramps to stop when input becomes inactive. A
valid start will override this command.
13
"10V in ctrl"
Selects 0-10V or ±10V control as the frequency reference. Start
source is not changed.
14
"20mA in ctrl"
Selects 4-20mA control as the frequency reference. Start source is
not changed.
15
"Anlg invert"
Inverts the scaling of the analog input levels set in
t211 [Anlg In 0-10V Lo] and t212 [Anlg In 0-10V Hi] or
t213 [Anlg In4-20mA Lo] and t214 [Anlg In4-20mA Hi].
16-27
Reserved
t211 [Anlg in 0-10V Lo]
Related Parameter(s): d020, P104, P108, t201, t202
Sets the analog input level that corresponds to P104 [Minimum freq] if a 0-10V input is used by P108
[Speed reference].
Analog inversion can be accomplished by setting this value larger than t212 [Anlg in 0-10V Hi] or by
setting t201 - t202 [Digital inx sel] to option 15 “Anlg invert”.
Values
Default:
0.0 %
Min/Max:
0.0/100.0 %
Display:
0.1 %
Summary of Contents for ILVFE-1W0075
Page 1: ......
Page 2: ...2 ILVFE series user manual...
Page 23: ...ILVFE series user manual 23...
Page 74: ...74 ILVFE series user manual Product dimensions Frame A Frame B Frame C...
Page 80: ...80 ILVFE series user manual...
Page 81: ......