38
ILVFE-series
user manual
Basic program group
P101 [Motor NP volts]
Related Parameter(s): d004, A453
Set to the motor nameplate rated voltage
Values
Default:
Based on drive rating
Min/Max:
20/Drive rated voltage
Display:
1 VAC
P102 [Motor NP hertz]
Related Parameter(s): A453, A444
Set to the motor nameplate rated frequency
Values
Default:
60 Hz
Min/Max:
10/400 Hz
Display:
1 Hz
P103 [Motor OL current]
Related Parameter(s): P111, t221, A441, A444, A448, A437
Set to the maximum allowable motor current.
The drive will fault on an F7 Motor Overload if the value of this parameter is exceeded by 150% for 60
seconds or 200% for 3 seconds.
Values
Default:
Based on drive rating
Min/Max:
0.0/(Drive rated amps x 2)
Display:
0.1 Amps
P104 [Minimum freq]
Related Parameter(s): d001, d002, d013, P105, t211, t213, A435
Set the lowest frequency the drive will output continously.
Values
Default:
0.0 Hz
Min/Max:
0.0/400.0 Hz
Display:
1 Hz
P105 [Maximum freq]
Related Parameter(s): d001, d002, d013, P104, A404, t212, t214, A435
Set the highest frequency the drive will output.
Values
Default:
60 Hz
Min/Max:
0/400 Hz
Display:
1 Hz
Stop drive before changing this parameter
Stop drive before changing this parameter
Stop drive before changing this parameter
Stop drive before changing this parameter