3.8.18.4 Set Temperature Threshold (
‘stt’
)
The
‘stt’
command defines the ‘on’ and ‘off’ temperature thresholds
that will trigger the camera to send temperature warnings. The
thresholds are in increments of 1 degrees C. If the camera’s ambient
temperature exceeds the ‘on’ temperature threshold, then the camera
will send a ‘Warning set – high temperature’ message to the Camera
Link’s serial interface. This message will be repeatedly sent every 60
seconds. The camera will subsequently send a ‘Warning cleared – high
temperature’ message when the temperature falls below the ‘off’
temperature threshold. The camera monitors these thresholds and
generates the warnings only when enabled via the
‘sta’
command.
Syntax:
stt <t1> <t2>
Parameter:
t1
’On’ threshold in degrees C.
t2
’Off’ threshold in degrees C.
Example:
stt 55 48
Instructs the camera to generate a
‘Warning set – high temperature’
message when the temperature exceeds
55C and a ‘Warning cleared – high
temperature’ when it reaches 48C.
3.8.18.5 Get Temperature Threshold (
‘gtt’
)
The
‘gtt’
command returns the current temperature threshold
settings.
Syntax:
gtt
Response:
t1 t2
Example:
gtt
User enters command.
55 48
Camera responds with current setting.
www.imperx.com
118
of
154
5/6/2005