LYNX Manual RA02
3.8.4 Long
Integration
3.8.4.1 Set Long Integration (
‘sli’
)
The
‘sli’
command sets the long integration timing.
Syntax:
sli <off|i>
Parameter:
off
Disables the long integration mode.
i
The long integration time in units of
mSeconds.
Range:
i
min=10
max=10,000
Example:
sli 750
Sets the long integration time to 750
msecs.
Notes:
Long integration operates in increments of 10
mSeconds and therefore will round the least
significant digit entered.
3.8.4.2 Get Long Integration (
‘gli’
)
The
‘gli’
command returns the current long integration setting.
Syntax:
gli
Response:
off|i
Example:
gli
User enters command.
750
Camera responds with current setting.
www.imperx.com
100
of
154
5/6/2005