3.8.7 Analog
Offset
3.8.7.1 Set Analog Offset (
‘sao’
)
The
‘sao’
command sets the analog offset of the camera.
Syntax:
sao <0|1|2> <i>
Parameter #1:
0
Sets both taps to the same offset.
1
Selects tap #1.
2
Selects tap #2.
Parameter #2:
i
The offset setting.
Range:
i
min=0,
max=255
Example:
sao 0 64
Sets the offset for both taps to 64.
3.8.7.2 Get Analog Offset (
‘gao’
)
The
‘gao’
command returns the current analog offset settings.
Syntax:
gao <0|1|2>
Parameter:
0
Selects both taps.
1
Selects tap #1.
2
Selects tap #2.
Response:
tap#1_offset tap#2_offset
Example:
gao 0
User enters command to get offset for
both taps.
64 64
Camera responds with both current
settings.
www.imperx.com
103
of
154
5/6/2005