LYNX Manual RA02
CAUTION NOTE
1. The
maximum
voltage
difference
between the strobe outputs is
8 volts!
2.
The maximum output current must not exceed 40mA!
+ 5.0V
FROM CAMERA
+ STROBE OUT
- STROBE OUT
R2
300
R1
1.0K
Q1
2N3904
C A M E R A
Figure 2.42 - Strobe Output Electrical Connection (Internal)
+ STROBE
- STROBE
+ 5.0V
Strobe
Active HIGH
1
2
STROBE OUT
BNC
+ STROBE
- STROBE
+ 5.0V
Strobe
Active LOW
1
2
STROBE OUT
BNC
R1
1.0K
R1
1.0K
Figure 2.43 – Recommended External Strobe Output Electrical Connection
www.imperx.com
71
of
154
5/6/2005