LYNX Manual RA02
Exposure Control
Command
Syntax
Parm#1
String
returned
Description
Get Shutter Time
gst
off|i
Returns the current shutter time:
off = disabled
i = shutter time in uSeconds
Get Long Integration
gli
off|i
Returns the current long integration time:
off = disabled
i = integration time in mSeconds
Get Frame Rate
gfr
off|i
Returns the current programmable frame
rate:
off = disabled
i = frame rate in frames per second
Trigger Control
Command
Syntax
Parm#1
String
returned
Description
Get Trigger
gtr
off|cc|et
s|f|d
Returns the current trigger mode setting:
off = disabled
cc = CC1
et = external
s = standard
f = fast
d = double
Get Trigger Duration
gtd
i
Returns the current number of frames to be
transmitted after a trigger event has
occurred. The valid range is 1 to 249. A
value of 250 – 255 indicates that the camera
is free running.
Get Pre Exposure
gpe
i
Returns the current pre-exposure in
uSeconds.
Get Double Exposure
gde
i
Returns the current double exposure in
uSeconds.
Get CC Integration
gci
off|on
Returns the current CC integration mode:
off = camera timing determines exposure
on = CC1 pulse width determines exposure