Table 32:
Pulse Generator parameters (continued)
Parameter Name
Type
Value
Access Description
PulseGenNumPulses
Integer
Min: 1
Max: 65535
RW
Sets number of pulses
to be generated by
Pulse Generator. To set
Pulse Generator in
continuous mode, set
the parameter in 65536
PulseGenEnable
Boolean
RW
Enables Pulse
Generator.
Canon Lens Control
Canon Lens Control is available in POE-C4410, POE-C5410, and POE-C6410 cameras.
Table 33:
General Canon Lens Control parameters
Parameter Name Type
Value
Access
Description
GetLensStatus
Command
WO
Requests value of Lens Status register.
LensStatus
Integer
RO
Returns status of Lens after GetLensStatus runs.
3.3.11.1 Controller Settings
Table 34:
Controller Settings
Parameter Name
Type
Value
Access Description
InitLens
Command
WO
This command initializes the
Canon Lens, if one mounted to
the camera
StopLens
Command
WO
Removes the power from the
Iris drive. Run InitLens
command to resume the lens
control
LensControllerStatus Enumeration
String
"InitLens_Failed"
"InitLens_Done"
Num.
0
1
RO
Shows status of Canon Lens
initialization
IrisRangeCheck
Enumeration
String
"Off"
"On"
Num.
0
1
RW
Enables internal checkout of Iris
Position and Step
LensPresenceCheck Enumeration
String
"Off"
"On"
Num.
0
1
RW
Enables or disables check of
lens presence
LensClockPolarity
Enumeration
String
"Negative"
"Positive"
Num.
0
1
RW
Sets polarity of Lens Clock