Cheetah Pregius Camera with GigE Vision
®
Interface – User Manual
August 27, 2019
Page
56
of
123
Rev 1.0
Table 23:
Acquisition Control parameters (continued)
Parameter Name
Type
Value
Access Description
TriggerType
Enumeration
String
"Standard"
"Fast"
Num.
0
1
RW
Standard:
Exposure and
readout sequential;
Fast:
Exposure and
readout overlapped
(see
TriggerNumFrames
Integer
Min: 1
Max: 65536
RW
Number of Frames
captured per Trigger.
(Available in Standard
Trigger mode only)
TriggerDelay
Integer
Min: 0
Max: 1000000
RW
Specifies delay between
Trigger to start of
exposure (in
microseconds)
Gain Control
Gain Control provides parameters for setting analog/digital gain and black level.
Table 24:
Gain Control parameters
Parameter Name
Type
Value
Access Description
Gain
Float
Min: 0.0
Max: 48.0
RW
Sets analog/digital gain in dB.
Increment is 0.1 dB.
BlackLevelAuto
Enumeration
String
"Off"
"Continuous"
Num.
0
1
RW
Sets the mode for Auto-Black
Level Adjustment
BlackLevel
Float
Min: 0
Max: 255
RW
Controls the analog black level
as an absolute physical value.
Adds a fixed analog offset to
the video level
DigitalGain
Float
Min: 1.00
Max: 4.00
RW
The pixel value is multiplied by
the Digital Gain Factor.
Increment is 0.01.
DigitalGainRaw
Integer
Min: 1024
Max: 4095
RW
Controls the raw value of
Digital Gain from 1024 (1x) to
4095 (4x) in steps of 0.001x
(Refer to section
for more information on
determining raw values)
DigitalOffset
Integer
Min: -512
Max: 511
RW
Adds a digital offset (+ or -) to
the video data.
DigitalOffsetRaw
Integer
Min: 0
Max: 1023
RW
Controls the Digital Offset in
RAW units.