Table 23:
Acquisition Control parameters (continued)
Parameter Name
Type
Value
Access Description
AcquisitionFrameRate
Float
RW
Controls acquisition rate
(in Hz) of frames
captured.
CurrentExposureTime
Integer
RO
Returns current
exposure time in
microseconds.
CurrentFrameTime
Integer
RO
Returns current frame
time in microseconds.
TriggerMode
Enumeration String
"Off"
"On"
Num.
0
1
RW
Enables Trigger mode of
operation. Not available
if
AcquisitionFrameRateEn
able parameter is “On”.
TriggerSoftware
Command
WO
Generates internal
trigger. TriggerSource
must be set to Software.
TriggerSource
Enumeration
String
"Line1"
"Line2"
"PulseGenerator"
"Software"
Num.
1
5
2
4
RW
Specifies internal signal
or external Line as
trigger source.
TriggerMode must be set
to “On” (refer to
for
more information).
TriggerActivation
Enumeration
String
"RisingEdge"
"FallingEdge"
Num.
0
1
RW
Specifies activation edge
of trigger.
TriggerDebounceTime
Integer
Min: 0
Max: 65535
RW
Specifies time period (in
microseconds) when a
second trigger is not
accepted.
TriggerFilterTime
Integer
Min: 0
Max: 65535
RW
Specifies the minimum
Trigger signal pulse
width. Any pulse shorter
than the selected time is
ignored
TriggerOverlap
Enumeration
String
"Off"
Num.
0
RO
Specifies the trigger
overlap mode, if the
camera receives a trigger
pulse while the camera is
still processing the
previous trigger.