Table 31:
Strobe 1 and Strobe2 parameters (some cameras may not support Strobe2)
Parameter Name Type
Value
Access Description
Strobe1Mode
Enumeration
String
"Off"
"EachFrame"
"OddFrame"
"EvenFrame"
Num.
0
1
2
3
RW
Sets the Strobe #1
mode of operation.
Strobe1Width
Integer
Min: 1
Max: Depends on CurrentFrameTime
and Strobe1Delay
RW
Sets Strobe 1 pulse
duration in
microseconds.
Strobe1Delay
Integer
Min: 10
Max: Depends on CurrentFrameTime
and Strobe1Width
RW
Sets Strobe 1 delay
from the reference,
in microseconds.
Strobe2Mode
Enumeration
String
"Off"
"EachFrame"
"OddFrame"
"EvenFrame"
Num.
0
1
2
3
RW
Sets the Strobe #2
mode of operation.
Strobe2Width
Integer
Min: 1
Max: Depends on CurrentFrameTime
and Strobe2Delay
RW
Sets Strobe 2 pulse
duration in
microseconds.
Strobe2Delay
Integer
Min: 10
Max: Depends on CurrentFrameTime
and Strobe2Width
RW
Sets Strobe 2 delay
from the reference,
in microseconds.
Pulse Generator
The camera provides an internal pulse generator for generating a trigger signal. You can
program it to generate a discrete sequence or a continuous trail of pulse signals.
Table 32:
Pulse Generator parameters
Parameter Name
Type
Value
Access Description
PulseGenGranularity
Enumeration
String
"x1uS"
"x10uS"
"x100uS"
"x1000uS"
Num.
0
1
2
3
RW
Sets the multiplication
factors of the Pulse
Generator where
x1 = 1 µS, x10=10 µS,
etc.
PulseGenWidth
Integer
RW
Sets pulse width of
Pulse Generator where
each unit is equal to
PulseGenGranularity.
PulseGenPeriod
Integer
RW
Sets pulse period of
Pulse Generator where
each unit is equal to
PulseGenGranularity.