Cheetah KAC Camera User Manual | Camera Link (CLF) Interface
October 1, 2019
Page
80
of
135
Rev 7.2
Figure 44: Pulse generator window.
Granularity:
Sets the granularity for the internal counters. Granularity can be set to 1x, 10x, 100x or
1000x.
Period
:
Sets the pulse period in microseconds.
Width
:
Sets the pulse width in microseconds.
# of Pulses
:
Sets the number of pulses generated. Two modes are available:
Continuous
– provides a continuous operation. To stop the process, you have to press
the “Stop” button.
Send # Pulses
– the user can set only a discrete number of pulses ranging (1 to 65500)
to be generated. To stop the process, you have to press the “Stop” button.
Otherwise, the process stops automatically after the last pulse is sent.
Process
:
Start
– starts and stops the process of Internal Pulse Generator. When the process is
in progress, the ‘Start” button becomes a ‘Stop” button.
Status
– provides the status of the process:
Red
– the process is on hold,
Green
– the process is working.
4.7.4 Strobe Control and Output Mapping
This window sets the camera strobe signals. Two independently controlled strobe signals
are supported – Figure 4.17.