Cheetah KAC Camera User Manual | Camera Link (CLF) Interface
October 1, 2019
Page
61
of
135
Rev 7.2
Pulse Generator Enable
This register enables the pulse generator.
Address
:
0x06A0
Data (0)
:
0 – disable pulse generator operation
1 – enable pulse generator operation
Data (31:1)
:
N/A
3.2.11 Test Pattern Workspace Registers
Test Mode Select
This register selects the test mode pattern.
Address
:
0x0428
Data (3:0)
:
000 – no test pattern
001 – steady horizontal image ramp
010 – steady vertical image ramp
011 – moving horizontal image ramp
100 – moving vertical image ramp
101– crosshairs superimposed over live image
110 – reserved
111 – reserved
Data (31:4)
:
N/A
3.2.12 Input/output Workspace Registers
OUT1 Output Polarity
This register sets the polarity (active Low or High) for the OUT1 output.
Address
:
0x0680
Data (0)
:
0 – active LOW
1 – active HIGH
Data (31:1)
:
N/A
OUT1 Output Mapping
This register maps the various internal signals to OUT1 camera output.
Address
:
0x0684
Data (2:0)
:
000 – no mapping
001 – trigger pulse
010 – pulse generator
011 – Strobe 1
100 – Strobe 2
1XX – reserved
Data (31:3)
:
N/A