III - Hardware Configuration
Before installing the module in a chassis, there are two features that must be selected
using DIP switches. These selections include the following:
•
Enable/Disable management on each port
(DIP switches 1, 2, and 3).
•
Configure the module to be either a standalone, a host, or a remote
(DIP switches 7 and 8).
DIP Switch Settings
Before installing the iMcV-FiberLinX-II, use the DIP switches to set the hardware-
configurable features. The DIP switches are located on switch S1 on the iMcV-
FiberLinX-II card. Refer to the diagram and table for switch settings and available
features.
Switch
Function
Default Setting
1
Management on EXT MGMT port
ON
2
Management on DATA port
OFF
3
Management on OPTICS or
UPLINK port
OFF
4
Factory use - Do not change OFF
5
Factory use - Do not change
OFF
6
Factory use - Do not change
OFF
7
Remote Module
OFF
8
Host Module
OFF
9
Factory use - Do not change
OFF
0
Factory use - Do not change
OFF
Host/Remote and Standalone Units
The iMcV-FiberLinX-II can be used as a Host, Remote, or Standalone unit. Refer to
the Application Examples section for examples.
When two iMcV-FiberLinX-II units are used as a pair, configure one as a Host unit
(DIP switch 8 = On) and the other as a Remote unit (DIP switch 7 = On). As a host
unit, the iMcV-FiberLinX-II requests management information from the attached
remote unit. It then displays that information, along with its own, when queried by
10