0 through 3 are low priority and settings of 4 through 7 are high priority. When the
Base VLAN Priority is set to 3, priority settings of 0 through 2 are low priority and
priority settings of 3 through 7 are high priority.
BrdCast Max Rate – This allows you to set the Broadcast Storm protection. Valid
values are 0-20% where 0% disables Broadcast Storm protection. The setting is the
percentage of line speed where broadcast frames will be dropped. For example, if
the setting is 1% and the unit detects that broadcast traffic is exceeding 1% of the line
speed then the unit will discard broadcast frames. The suggested setting is 1%.
Bandwidth Configuration—bw
The iMcV-FiberLinX-II allows you to view bandwidth status and to configure
bandwidth from a serial connection or a Telnet session. In the Main Configuration
screen, press the space bar, type bw and press Enter to access the Bandwidth Control
Settings screen:
------------------------- Bandwidth Control Settings -----------------------------
Optics Port Data Port
Bandwidth Limit, 0 For None
0 0
RX
Bandwidth Limit, 0 For None
0 0
TX
it RateControl Enable/Disable
Disable
Un
ge Value.
Use
Arrow Keys
To Move Cursor. Press Space Bar To Chan
Press
RETURN
To Set New Value. Press
Q
or
F4
to Exit.
This screen includes the following parameters:
•
Receive Bandwidth Limit
•
Transmit Bandwidth Limit
•
Unit Rate Control
RX Bandwidth Limit - This allows you to set the receive bandwidth limit (up to 100
Mbps) for both the DATA and OPTICS (or UPLINK) ports. Entering a setting of either
0 or 100,000,000 will result in a limit of 100 Mbps. When the received data reaches
the set limit in a one second interval, the unit stops receiving data. If flow control is
enabled, then flow control begins prior to reaching the set limit.
TX Bandwidth Limit – This allows you to set the transmit bandwidth limit (up to 100
Mbps) for both the DATA and OPTICS (or UPLINK) ports. Entering a setting of either
0 or 100,000,000 will result in a limit of 100 Mbps. When the transmit data reaches
the set limit in a one second interval, the unit stops transmitting data, but will
continue to receive until all the internal buffers are filled. If flow control is enabled,
then flow control begins before all the buffers are filled.