Port VLAN Filter
This parameter allows you to pass traffic with up to 32 separate VLAN IDs between
the OPTICS (or UPLINK) port and the DATA port. To enable the Data VLANS fields,
you must enter Y in the Tags column for both the Optics and Data rows. Enter up to
32 VLAN IDs in the Data VLANs fields.
Unit Configuration—unit
The iMcV-FiberLinX-II allows you to view unit status as well as configure some unit
features by using a serial connection or a Telnet session. In the Main Configuration
screen, press the space bar, type unit, and press Enter to open the Unit Control
Settings screen. In this screen you can view the unit FlowControl, FiberAlert/LinkLoss,
Loopback, Maximum Frame Size, and 802.1p Base Priority (logging-in as a User in a
Telnet session allows you to view these settings but prevents you from changing the
settings).
Saved VLAN Values <Active after reboot>. Current VLAN Values <Active now>.
Tags
VLAN IDs Priorities
Current Saved Current Saved
Ports Data VLANs are used only
Optics [0 ] [
0
] [0 ] [
0
] [
Y
] if Tags are enabled on both
e Optics and Data Ports.
Data [0 ] [
0
] [0 ] [
0
] [
Y
] th
Management VLAN EXT Mgmt Tag
NMP [0 ] [
0
] [0 ] [
0
] [
N
]
S
Data VLANs <Optics <----> Data>
VLAN 1 [0 ] [
900
] VLAN 12 [0 ] [
911
] VLAN 23 [0 ] [
922
]
VLAN 2 [0 ] [
901
] VLAN 13 [0 ] [
912
] VLAN 24 [0 ] [
923
]
VLAN 3 [0 ] [
902
] VLAN 14 [0 ] [
913
] VLAN 25 [0 ] [
924
]
VLAN 4 [0 ] [
903
] VLAN 15 [0 ] [
914
] VLAN 26 [0 ] [
925
]
VLAN 5 [0 ] [
904
] VLAN 16 [0 ] [
915
] VLAN 27 [0 ] [
926
]
VLAN 6 [0 ] [
905
] VLAN 17 [0 ] [
916
] VLAN 28 [0 ] [
927
]
VLAN 7 [0 ] [
906
] VLAN 18 [0 ] [
917
] VLAN 29 [0 ] [
928
]
VLAN 8 [0 ] [
907
] VLAN 19 [0 ] [
918
] VLAN 30 [0 ] [
909
]
VLAN 9 [0 ] [
908
] VLAN 20 [0 ] [
919
] VLAN 31 [0 ] [
930
]
VLAN 32 [0 ] [
931
]
VLAN 10 [0 ] [
909
] VLAN 21 [0 ] [
920
]
VLAN 11 [0 ] [
910
] VLAN 22 [0 ] [
921
]
7.
Valid VLAN IDs are between 1 and 4094. Valid priorities are between 0 and
Type S or F3 to save the changes. Type Q or F4 to quit and cancel changes.
------------------------- Unit Control Settings -----------------------------
nit FlowControl
Disable FlowControl Globally
U
nit FiberAlert
TXLinkLoss Plus FXLinkLoss Enabled
U
nit LoopBack
No LoopBack, Normal Traffic Mode
U
nit Max FrameSz
Oversized Frames:
1536
U
02.1p Base Pri
Base Priority 4
8
rdcast Max Rate
Max Broadcast rate 1%
B
B
ange Value.
Use
Arrow Keys
To Move Cursor. Press
Space ar
To Ch
Press
RETURN
To Set New Value. Type
Q
or
F4
to Exit.
Unit FlowControl – This allows you to enable/disable Flow Control functionality on
the unit. You must enable this to use Flow Control on any port. The settings include
the following:
•
Disable FlowControl Globally
30