EtherType (optional). These values must be identical on both iMcV-FiberLinX-II
modules.
The Data Tag is [8 ]
Data Priority is [0 ]
Are Extra Tags left on the Data Port? [ N ]
Select the TPID for the Extra Tag 1 = 8100, 2 = 9100, 3 = 9200
Extra Tag TPID [ 1 ] [8100]
4.
On the Host iMcV-FiberLinX-II module, enter Y in the
Are Extra Tags left
on the Data Port?
field to only accept the Extra Tag VLAN ID on the DATA
port. On the Remote iMcV-FiberLinX-II module, enter N to have the Extra Tag
VLAN ID added to incoming and removed from outgoing data on the DATA
port.
5.
Select the Extra Tag TPID EtherType (optional).
6.
Press S or F3 to save the settings.
7.
Type reboot. Repeat steps for second module.
Now the iMcV-FiberLinX-II Host/Remote pair is configured to pass only VLAN ID 8
data from the Host iMcV-FiberLinX-II to the Remote iMcV-FiberLinX-II where the
VLAN ID 8 tag is removed before sending the data out of the Remote DATA port.
The Extra Tag VLAN ID 8 is added to all data received on the Remote DATA port
before being sent to the Host iMcV-FiberLinX-II where the VLAN ID 8 tag remains on
the data leaving the Host DATA port.