Three-Digit
Formatting (SW1
Pole 6)
The SW1 Pole 6 bit provides a selectable parameter “native” to Sandar, which
allows you to specify how many digits (2 or 3) with which values for Matrix and
Status Response messages are formatted. The factory default is to set this bit to
the ON position.
When bit 6 is ON, source and destination values will be formatted with 3 digits
(for example: 001).
Here is an example of a Status response message formatted in 3-digit
mode: SA:001,002,003,004,005,006,007,008.
Here is an example of a Matrix message formatted in 3-digit mode:
M001:001,002,003,004,005,006,007,008.
When bit 6 is OFF, source and destination values will be formatted with 2 digits
(for example: 01).
Here is an example of a Status response message formatted in 3-digit
mode: SA:01,02,03,04,05,06,07,08.
Here is an example of a Matrix message formatted in 3-digit mode:
M01:01,02,03,04,05,06,07,08.
Device IDs (SW1
Poles 7 and 8)
The SW1 Poles 7 and 8 provides a selectable address range. Sandar protocols
require a device to have two addresses starting at the value 8200. The addresses
are referred to as the Poll Address (which is always odd) and the Data Address
(which is always even).
The Harris Device ID (which is seen by Harris products on the X-Y bus) is the
DIP switch value (see
Table 4-24
on page 121).
The Poll Address of the P12×1-SP is the constant value 8200 added to the DIP
switch value selected (see
Table 4-24
on page 121).
The Data Address is equal to the Poll Address plus 1 (see
Table 4-24
on
page 121).
Table 4-24
on page 121 shows SW1 poles 7 and 8 DIP switch settings with
corresponding Harris device IDs, Poll Addresses, and Data Addresses.
Protocol Com-
mands
The SANDARTOLXY protocol supports the following Prosan message types. These
message types are explained in detail in subsequent sections.
Alarm
Text Name
Matrix Status
Table 4-24
SANDARTOLXY Device IDs
SW1 Poles 7 / 8
DIP Switch
settings
Harris Device ID
(DIP Switch
value)
Poll Address
Data Address
00
01
8201
8202
01
03
8203
8204
10
05
8205
8206
11
07
8207
8208