C O M M A N D R E F E R E N C E
Command Reference
04_09
LDC-3700C Series
123
C H A P T E R
4
The TEC:GAIN? query returns the value of the control loop gain.
Notes
If a value other than 1, 3, 10, 30, 100, or 300 is entered via the GAIN command, the
nearest valid value will be stored.
Examples
"TEC:Gain?" -response: 30.0, means the control loop gain is set to 30.
"Tec:GAIN?" -response: 100.0, means the control loop gain is set to 100.
The TEC:ITE command sets the TEC control current set point. It is also used to enter the
TEC current calibration value.
Parameters
An <nrf value> which represents the ITE set point current, in Amps. In ITE current
calibration mode, the <nrf value> represents the measured current value in Amps.
Notes
This set point is used by the TEC's constant ITE mode only.
In local operation, the ITE set point is entered by selecting (ADJUST) TEC and ITE
modes, pressing the (TEC DISPLAY) SET switch, adjusting the ADJUST knob (within 3
seconds), and then releasing the SET switch when the desired value is shown on the
TEC display.
Examples
"TEC:ITE 1" -action: sets the TEC output current set point to 1.000 Amps.
"TEC:MODE:ITE; Tec:Ite 3.5" -action: sets the TEC output current set point to 3.500
Amps and the output is controlled to that value.
The TEC:ITE? query returns the value of the measured TEC output current.
Notes
The TEC load current is constantly measured and updated, regardless of the TEC mode
of operation.
This measurement is updated approximately once every 600 msec.
If an external booster is used, the ITE measurement will remain zero, as the internal
output section is disabled in that case.
In local operation, the ITE measured value is determined by pressing the ITE switch in
the TEC DISPLAY area of the front panel, and visually reading the value on the TEC
display.
Examples
"TEC:ITE?" -response: 2.43, means the measured TEC output current is 2.430 Amps.
"Tec:Ite?" -response: -3.27, means the measured TEC output current is -3.270 Amps.
TEC:GAIN?
C
OMMON
D
EVICE
D
EPENDENT
F
RONT
P
ANEL
TEC:ITE
C
OMMON
D
EVICE
D
EPENDENT
F
RONT
P
ANEL
TEC:ITE?
C
OMMON
D
EVICE
D
EPENDENT
F
RONT
P
ANEL
Summary of Contents for LDC-3700C Series
Page 2: ......
Page 8: ...L I S T O F FIG U R E S vi LDC 3700C Series...
Page 10: ...L I S T O F TA B L E S viii LDC 3700C Series...
Page 78: ...RE M O T E O PE R A T I ON Command Syntax 62 LDC 3700C Series C H A P T E R 3...
Page 150: ...C O M M A N D RE F E R E N C E Command Reference 134 LDC 3700C Series C H A P T E R 4...