DNS-33W
DNS-33W 0503 VOL1 (E)
5 - 12 5. SETTINGS AND ADJUSTMENT OF CAMERA
1.
Press and hold the PRESET button with a pointed stick,
for example the tip of a ballpoint pen. The following
message is displayed:
PRESET FILE SELECT
(ENGINEER SET FILE)
2.
Rotate the rotary pulse switch to scroll to "FACTORY
SET FILE" and press the SET button.
The following message is displayed:
PRESET FILE SELECT
(FACTORY SET FILE)
HOLD PRESET SW
→
LOAD
3.
Press and hold the PRESET button again. The following
message is displayed and preparation for the initialization
is started.
Keep holding the PRESET button while "PLEASE
HOLD" message is displayed. When the PRESET button
is released, "STOP!" message appears and the
initialization stops. After preparation for the initialization
is completed, the file loading is started automatically.
---PRESET PROCESS---
FACTORY SET FILE LOAD
PLEASE HOLD >>>>>>>>
4.
After the file loading is completed and the following
message is displayed, "CAMERA RESTART" is
displayed, the camera is restarted, and the camera settings
return to the factory settings.
FACTORY SET FILE LOAD
COMPLETED
Notice
Selecting "CANCEL" on the first message and
pressing the SET button will cancel the initialization.
Also, not pressing the PRESET button again for 10
seconds while the first or second message is
displayed will end the message display and cancels
the initialization.
5.10 Settings in the Menu
There are two menu modes available for DNS-33W: "Normal
Menu" and "Maintenance Menu". These setting modes can set
up various status of the camera such as items displayed on
the VF to suit the shooting situation. The selection and set up
of each item are performed by displaying operation menu
screen on the VF or the monitor.
5.10.1 Basic Operations of the Menu Screen
■
Operation of the "Normal Menu"
This section explains how to operate the Normal Menu.
FIELDPAK
GAIN
OUTPUT
AWB
STBY
SAVE
・
L
・
M
・
H
CAM
BARS
・
A
・
B
OFF
POWER
VF
CHARA
VF CHARA Button
SET Button
Camera Right Side
Camera Front Side
Rotary Pulse Switch
1.
Press and hold the VF CHARA button on the right side
of the camera, and press the SET button on the front part,
still holding the VF CHARA button.
The Normal Menu is displayed as shown in the figure
below. Press the VF CHARA button again to end the
Normal Menu.
VF DISPLAY
MONITOR OUT
ZEBRA INDICATOR
!INDICATOR
BARS TITLE/MODE
LOW/MID/HIGH GAIN MODE
BATT/DISK WARNING
SCENE FILE
LEVEL ADJUST
OTHERS
Normal Menu
Flashing
Cursor
***
MENU
***
2.
Rotate the rotary pulse switch and put the flashing cursor
on the menu item to set up.
3.
Press the SET button to confirm the selected item.
When the selected item is confirmed, the screen
automatically switches to the submenu screen, and
detailed setting items can be modified there.
Summary of Contents for Editcam 3 DNS-33W
Page 2: ......
Page 8: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 10: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 12: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 28: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 48: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 60: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 74: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 116: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 136: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 154: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 156: ...DNS 33W DNS 33W 0503 VOL1 E...
Page 158: ......
Page 159: ......