83
BS-98 1409 VER1 (U) (E)
5.1 Settings from the BS Menu
FUNCTION SETTING
FUNCTION SETTING sets the various function settings.
▲
HDTV VIDEO PROCESS
SDTV VIDEO PROCESS
HD PM VIDEO PROCESS
SD PM VIDEO PROCESS
FUNCTION SETTING
ENGINEER SET FILE RENEW
PROGRAM UPDATE
▼
*** ENGINEER(2/2) ***
ARCNET ID SET 1
CAM PGM NO. ENABLE OFF
CAM PGM NO. SET −−−
BS FRONT ID DISPLAY OFF
PM TALLY SEL Y
CAM CODE −−−
SAFETY&H.PWR −−−
REPEATER MODE −−−
FUNCTION SETTING
To position the
fl
ashing cursor on the
"FUNCTION SETTING", and determine.
The submenu "FUNCTION SETTING"
is displayed, on which you can perform
various settings.
Setting Item
Set Value
Description
ARCNET ID SET
1 to 255
Sets the NETWORK ID of ARCNET (10 decimal).
CAM PGM NO. ENABLE
OFF / ON
It sets whether or not the camera program number is controlled by CCU/BS.
CAM PGM NO. SET
OFF / 1 to 99
Sets the camera program number.
BS FRONT ID DISPLAY
OFF
The seven segment displays at the front side of the equipment do not display anything.
ARC ID
The seven segment displays at the front side of the equipment displays ARCNET
NETWORK ID (HEX).
PGM NO.
The seven segment display at the front side of the equipment displays the camera
program number.
PM TALLY SEL
Y
Assign the TALLY OUT (PM TALLY) pin "C" to the Y TALLY control.
COMM
Assign the TALLY OUT (PM TALLY) pin "C" to the Red/Green TALLY common control.
CAM CODE
−
Regional options
SAFETY&H.PWR
−
Regional options
REPEATER MODE
−
Regional options
CAM PWR CONT
−
Regional options
Q-TV MODE
Changes
depending on the
FORMAT.
It set and displays the analog QTV band width and the number of channels.
HD TRUNK
ON / OFF / ---
ON/OFF setting of the HDTV TRUNK VIDEO line. It is enabled only when the 3G-
compatible camera is connected and when the 1.5G format is operating.
HD Q-TV
ON / OFF / ---
ON/OFF setting of the HDTV QTV VIDEO line. It is enabled only when the 3G-compatible
camera is connected.
WARNING BIG CHAR
OFF / ON
The warning item for the self-diagnosis result (DIAGNOSTIC INFORMATION) is displayed
in a big character.
FIBER SINGLE MODE
OFF / ON
It sets ON/OFF of the fiber single mode.
For ARCNET and the camera program number, refer to the manuals of the control panel and the camera head that correspond to
the network.
NOTE:
Turn on the "HEAD POWER" switch of the front panel of CCU whenever CCU operaters "FIBER SIGNAL MODE".
Summary of Contents for BS-98
Page 1: ...Base Station BS 98 OPERATION MANUAL Products conforming to RoHS directive ...
Page 2: ......
Page 14: ...x BS 98 1409 VER1 U E ...
Page 15: ...1 OUTLINE ...
Page 16: ...2 BS 98 1409 VER1 U E ...
Page 22: ...8 BS 98 1409 VER1 U E ...
Page 24: ......
Page 25: ...2 NAME and FUNCTION ...
Page 26: ...12 BS 98 1409 VER1 U E ...
Page 38: ...24 BS 98 1409 VER1 U E ...
Page 39: ...3 FORMATS and GENLOCK ...
Page 40: ...26 BS 98 1409 VER1 U E ...
Page 49: ...4 EQUIPMENT CONNECTIONS ...
Page 50: ...36 BS 98 1409 VER1 U E ...
Page 67: ...5 BS SETTINGS and ADJUSTMENT ...
Page 68: ...54 BS 98 1409 VER1 U E ...
Page 103: ...6 TROUBLE SHOOTING and MAINTENANCE ...
Page 104: ...90 BS 98 1409 VER1 U E ...
Page 112: ...98 BS 98 1409 VER1 U E ...
Page 114: ...100 BS 98 1409 VER1 U E ...
Page 116: ......
Page 117: ......