87
BS-98 1409 VER1 (U) (E)
5.2 Settings Using Switches on the Module
5.2 Settings Using Switches on the Module
It is necessary to set hard switches of each module according to the external system connected to CCU/BS.
Tally Mode Settings
Set the mode of the tally control signal input to the COMMUNICATION connector on the rear of the CCU/BS.
Switching is executed with S1 to S3 of the IO module.
POWER MAKE
S1
S2
S3
IO Module
Switch No.
Function Name
Setting
Description
S1
R TALLY
POWER
Sets the R TALLY signal input to the CCU/BS to "POWER mode".
MAKE
Sets the R TALLY signal input to the CCU/BS to "make contact mode".
S2
G TALLY
POWER
Sets the G TALLY signal input to the CCU/BS to "POWER mode".
MAKE
Sets the G TALLY signal input to the CCU/BS to "make contact mode".
S3
Y TALLY
POWER
Sets the Y TALLY signal input to the CCU/BS to "POWER mode".
MAKE
Sets the Y TALLY signal input to the CCU/BS to "make contact mode".
Summary of Contents for BS-98
Page 1: ...Base Station BS 98 OPERATION MANUAL Products conforming to RoHS directive ...
Page 2: ......
Page 14: ...x BS 98 1409 VER1 U E ...
Page 15: ...1 OUTLINE ...
Page 16: ...2 BS 98 1409 VER1 U E ...
Page 22: ...8 BS 98 1409 VER1 U E ...
Page 24: ......
Page 25: ...2 NAME and FUNCTION ...
Page 26: ...12 BS 98 1409 VER1 U E ...
Page 38: ...24 BS 98 1409 VER1 U E ...
Page 39: ...3 FORMATS and GENLOCK ...
Page 40: ...26 BS 98 1409 VER1 U E ...
Page 49: ...4 EQUIPMENT CONNECTIONS ...
Page 50: ...36 BS 98 1409 VER1 U E ...
Page 67: ...5 BS SETTINGS and ADJUSTMENT ...
Page 68: ...54 BS 98 1409 VER1 U E ...
Page 103: ...6 TROUBLE SHOOTING and MAINTENANCE ...
Page 104: ...90 BS 98 1409 VER1 U E ...
Page 112: ...98 BS 98 1409 VER1 U E ...
Page 114: ...100 BS 98 1409 VER1 U E ...
Page 116: ......
Page 117: ......