96
BS-98 1409 VER1 (U) (E)
6.2 ALARM Indicator on the Control Panel Flashes ON and OFF
■
List of Self Diagnostic Information
The following tables list the self diagnostic information for the standard speci
fi
cation.
List of Self Diagnostic Information
Diagnosed Item
Description
Diagnosis Result
Meaning
Head Power
Power status of the camera head
ON
The camera head is powered ON.
OFF
The camera head is powered OFF.
Head Fan
Rotating status of fan of the camera
head or FA (Fiber Adaptor)
AUTO SSLOW
Super-slow in auto mode
AUTO SLOW
Slow in auto mode
AUTO NOR
Normal in auto mode
AUTO FAST
Fast in auto mode
SSLOW
Super-slow in manual mode
SLOW
Slow in manual mode
NOR
Normal in manual mode
FAST
Fast in manual mode
NG
Fan has stop.
Head Temp
Internal temperature of the camera
head
OK
Normal
NG
The temperature is abnormally high or the
difference between the internal temperature
and outside-air temperature is at least 25°C.
Head Battery
Status of the battery in the MPU
module of the camera head
OK
Normal
NG
The backup battery voltage is low.
Head Memory
Status of the RAM in the MPU module
of the camera head
OK
Normal
NG
Data in the module is destroyed
BS Fan
Rotating status of the fans on the rear
and inside of the BS
OK
Normal
NG
Internal cooling fan either has stopped.
BS Temp
Internal temperature of the BS
OK
Normal
NG
The temperature is abnormally high or the
difference between the internal temperature
and outside-air temperature is at least 25°C.
BS Battery
Status of the battery in the BS CONT/
REF module
OK
Normal
NG
The backup battery voltage is low.
BS Memory
Status of the RAM in the BS
MPU&REF module
OK
Normal
NG
Data in the module is destroyed.
BS >>> Head
(BS to Head
transmission)
OPT Level
Optical signal level sent from the BS
to the camera head (Detect the optical
receiving level at the camera head
side and display the status).
OK
Good
ATTEN
The amount of light received decreased.
WARN
The amount of light received significantly
decreased.
NG
Light cannot be received.
SDI Status
Status of SDI signal
OK
The format is normal and there is no CRC error.
NG
The format is abnormal or there is a CRC error.
Comm Status
Status of the command signal sent
from the BS to the camera head
OK
Normal
NG
No command signals are sent, or a CPU error
occurs.
Head >>> BS
(Head to BS
transmission)
OPT Level
Optical signal level sent from the
camera head to the BS (Detect the
optical receiving level at the BS side
and display the status).
OK
Good
ATTEN
The amount of light received decreased.
WARN
The amount of light received significantly
decreased.
NG
Light cannot be received.
SDI Status
Status of SDI signal
OK
The format is normal and there is no CRC error.
NG
The format is abnormal or there is a CRC error.
Comm Status
Status of the command signal sent
from the camera head to the BS
OK
Normal
NG
No command signals are sent, or a CPU error
occurs.
Summary of Contents for BS-98
Page 1: ...Base Station BS 98 OPERATION MANUAL Products conforming to RoHS directive ...
Page 2: ......
Page 14: ...x BS 98 1409 VER1 U E ...
Page 15: ...1 OUTLINE ...
Page 16: ...2 BS 98 1409 VER1 U E ...
Page 22: ...8 BS 98 1409 VER1 U E ...
Page 24: ......
Page 25: ...2 NAME and FUNCTION ...
Page 26: ...12 BS 98 1409 VER1 U E ...
Page 38: ...24 BS 98 1409 VER1 U E ...
Page 39: ...3 FORMATS and GENLOCK ...
Page 40: ...26 BS 98 1409 VER1 U E ...
Page 49: ...4 EQUIPMENT CONNECTIONS ...
Page 50: ...36 BS 98 1409 VER1 U E ...
Page 67: ...5 BS SETTINGS and ADJUSTMENT ...
Page 68: ...54 BS 98 1409 VER1 U E ...
Page 103: ...6 TROUBLE SHOOTING and MAINTENANCE ...
Page 104: ...90 BS 98 1409 VER1 U E ...
Page 112: ...98 BS 98 1409 VER1 U E ...
Page 114: ...100 BS 98 1409 VER1 U E ...
Page 116: ......
Page 117: ......