iGuard FPS110
P.8
Connections – Power & external controls
iGuard provides easy-access terminals for connections to external controls, including
Door Strikes, Door Sensor, Door Open Switch, and External Alarm.
Power (12V DC):
Terminals #1 (ground) & #2 (+12V).
The power requirement is 12V DC, 150mA (idle),
500mA (peak).
Door Strike (Terminal 3 – 5):
(3 - 4 Normal Open, 4 - 5 Normal Close). These terminals are connected directly to
the internal relay, rating at 12V / 1A. If the door strike is within this current limit, it can
be directly connected to these terminals. If the system is used solely for Time
Attendance System, these terminals can be left disconnected.
Door Sensor (optional):
Terminals #6 & #7
. It provides iGuard the current status of the door (open / close). If
the door is left open for over 10 seconds, iGuard will generate beep sounds to alert
others.
Open Door Switch (optional):
Terminals #8 & #9
. An optional door switch can be connected to these terminals. It is
used to open the door remotely, such as opening the door from the inside of the
business premises, or from the reception area.
External Alarm (optional):
Terminals #10 & #11
. This is used for the optional external alarm. If the case of the
device is forced open during operation (such as a break-in), an internal sensor will
trigger this connection, and it will sound the external alarm.