52
2
INSTALLATION PROCEDURE
302.061
ERROR
CAUSE
SOLUTION
Signals that the charge of the PLC
batter is low.
Battery charge low.
Replace the battery within one day
(See Chapter 9 of the Use and
Maintenance Manual).
ERROR
SOLUTION
It indicates that the bar guide is not in the correct
position.
Using the keyboard controls, regain the correct position by
lowering the bar pusher.
ERROR
SOLUTION
It indicates that the bar pusher is not in the correct
position.
Using the keyboard controls, regain the correct position.
ERROR
CAUSE
SOLUTION
The bar pusher did not move from
the "UPWARD" to the
"DOWNWARD" position.
The movement is hindered by an
obstacle.
Remove the obstacle.
The
S2
microswitch (the bar pusher
downwards device) is out of position
or damaged.
Check the microswitch position or
replace the microswitch.
45
P L C
b a t t e r y
e x h a u s t e d
46
B a r
f e e d e r
l i f t e d
47
B a r
d r o p
c o n t r o l
o n
48
B a r
p u s h e r
u p w a r d
Summary of Contents for VIP 80
Page 1: ...REL DATA COD S N VIP 80 MANUAL FOR USE AND MAINTENANCE GB 1 03 11 99 805005440 ...
Page 28: ...HANDLING AND INSTALLATION 4 25 302 028 ...
Page 61: ...PUSH BUTTON PANEL OPERATION GUIDE GB 03 11 99 VIP 80 AUTOMATIC BAR FEEDER ...
Page 64: ...2 302 061 ...
Page 74: ...12 1 GENERAL INFORMATION 302 061 ...
Page 136: ......
Page 138: ......
Page 142: ...302 061 B ...
Page 144: ......
Page 148: ......
Page 150: ......
Page 152: ......