MACHINE MAINTENANCE
7
30
2.
0
2
8
- 47 -
7.2.
PERIODIC MAINTENANCE - TABLE
7.2.1
Air filter unit - Check
❑
Filter (A)
– Check if cup
B
is not full of condensate. If need be,
drain through valve
C
.
❑
Lubricator (D)
– Make sure that the oil level is not under the height of
suction.
To top up, do the following:
– disconnect the compressed air supply;
– unscrew plug
E
or cup
F
to fill the tank; the oil level
shall reach the
MAX
. reference.
Oil properties: 9 to 11 cSt at 40°C ISO VG 10.
– Reset the compressed air supply.
– Check the air lubrication (1-12 drops per 1000 l air);
adjust through screw
G
.
FEEDER
SECTION
OPERATIONS
FREQUENCY
HOURS
Periodically
200 1250 2000
Feed chain
Tension check
and adjust-
ment
•
Air filter
Check
•
Revolving tip
Check
•
AIR LUBE OIL COMPARATIVE TABLE
BP ENER-
GOL HP10
SHELL
TELLUS C10
MOBIL
DTE 21
ESSO
SPINESSO 10
28.081 Ec.0
MAX
•
A
G
E
•
F
•
B
C
D