2. Installation & wiring
3. Functions
4. Support tool
Appendix
1. Overview
5-8
Control commands list
No.
Name
Control command
Description
Prefix
Mnemonic
Suffix
40
Get communication
settings
(Current value)
^
comgetc
CR
LF
Gets the RS-232 interface communication settings. (Current
value)
Example: Response when getting the current values of the
communication settings
^07,01,01,00,00/00,00,00,00/5e,00,00,00/0d,
0a,00,00 CR
LF
(^baud rate, data length, parity, stop bits, flow control/
reserved, add check digit, uppercase response, re-
served/4 prefixes/4 suffixes
CR
LF
)
For details, refer to
P. 5-9 "Detailed response exam-
.
41
Get communication
settings
(Memory value)
^
comgetm
CR
LF
Gets the RS-232 interface communication settings. (The
setting values applied at startup)
Example: Response when getting the communication settings
applied at startup
^07,01,01,00,00/00,00,00,00/5e,00,00,00/0d,
0a,00,00 CR
LF
(^baud rate, data length, parity, stop bits, flow control/
reserved, add check digit, uppercase response, re-
served/4 prefixes/4 suffixes
CR
LF
)
For details, refer to
P. 5-9 "Detailed response exam-
.
z
The prefix and suffix listed in the control commands list are the factory default settings.
z
When "save setting values" is executed, the non-volatile memory is overwritten. Keep in mind that the
non-volatile memory can be overwritten 100,000 times.