2. Installation & wiring
3. Functions
4. Support tool
Appendix
1. Overview
5-9
Control commands list
Detailed response examples
z
No. 36 Get selection number (current value)
Prefix
Selection num-
ber
(Current value)
Suffix
^
0
CR
LF
Selection number is a numeric value from "0" to "7".
z
No. 37 Get selection number (memory value)
Prefix
Selection num-
ber
(Memory value)
Suffix
^
0
CR
LF
Selection number is a numeric value from "0" to "7".
z
No. 39 Get version
Prefix
Model number
Separator
Main application
version
Separator
Bootloader ver-
sion
Suffix
^
WB1F-100S1S
/
A-001.000.00
/
B-001.000.00
CR
LF
The model number is "WB1F-100B1S" for the RS-232 type and "WB1F-100S1S" for the USB type.
The main application version is the numeric values in the format 3-digit.3-digit.2-digit that follow A- which indicates the
main application.
The bootloader version is the numeric values in the format 3-digit.3-digit.2-digit that follow B- which indicates the boot-
loader.
z
No.40 Get communication settings (current values), No. 41 Get communication settings (memory values)
Prefix
RS-232 settings
Separator
Communication
speed
Data length
Parity
Stop bits
Flow control
^
03,
01,
01,
00,
00
/
Communication command
Separator
Reserved
Check digit addi-
tion
Uppercase
response
Reserved
00,
00,
00,
00
/
Communication command
Separator
Prefix
Prefix
Prefix
Prefix
5e,
00,
00,
00
/
Communication command
Suffix
Suffix
Suffix
Suffix
Suffix
0d,
0a,
00,
00
CR
LF
The RS-232 settings are the setting values in
"3. 5 Configuration item table"
.
The communication command is the setting values in
"3. 5 Configuration item table"
.