2. Installation & wiring
Function
4. Support tool
5. Appendix
1. Overview
3-37
Configuration item table
Item
Sub item
Address
(hex)
Size
(dec)
Default
(hex)
Setting value
(hex)
Remarks
OK/NG output
settings
OK output/reading
linked control
0120
1
01
00: Disabled
01: Enabled
Enable to link to the reading
operation.
Reserved
0121
1
-
-
OK output
polarity
0122
1
01
00: Off
01: On
On: The transistor is turned on
and current flows.
Off: The transistor is turned off
and the circuit is open.
When the setting value is changed,
it is immediately reflected in the
OK output.
OK output
duration
0123
1
0A
00:
Infinity
01-FF: Setting value by 10ms step
(10 ms to 2,550 ms)
NG output/reading
linked control
0124
1
01
00: Disabled
01: Enabled
Enable to link to the reading
operation.
Reserved
0125
1
-
-
OK/NG output
settings
NG output
polarity
0126
1
01
00: Off
01: On
On: The transistor is turned on
and current flows.
Off: The transistor is turned off
and the circuit is open.
When the setting value is changed,
it is immediately reflected in the
NG output.
NG output
duration
0127
1
0A
00: Infinity
01-FF:Setting value by 10ms step
(10 ms to 2,550 ms)
Reserved
0128-012F
8
-
-
External trigger
input settings
Reading start with
External trigger input
0130
1
01
00: Disabled
01: Enabled
Enable when you want to
perform reading with an external
trigger input operation.
External trigger input
active level
0131
1
01
00: High
01: Low
External Trigger
input filter time
0132
1
20
01-20 (1ms to 32ms)
Start reading barcode by turn-
ing external trigger input on for
longer than the setting value.
To shorten the setting value
may affect noise resistance, so
fully evaluate this when using
product.
Reserved
0133-013F
13
-
-
PWM output
settings
PWM output reading
linked control when
successful
0140
1
01
00: Disabled
01: Enabled
Enable to link to the reading
operation.
Reserved
0141
1
-
-
PWM output
frequency when
successful
0142
2
D0
0014-4E20: Setting value Hz
(20 Hz to 20,000 Hz)
Lower byte setting
0143
07
Upper byte setting
PWM output
duration
when successful
0144
1
14
00:
Infinity
01-FF: Setting value by 10ms step
(10 ms to 2,550 ms)
Open state when the output stops.
PWM output duty
when successful
0145
1
32
01-63: Setting value %
(1% to 99%)
Set the percentage when on.
Reserved
0146
1
-
-
Reserved
0147
1
-
-
PWM output reading
linked control when
failed
0148
1
01
00: Disabled
01: Enabled
Reserved
0149
1
-
-