2. Installation & wiring
3. Functions
4. Support tool
Appendix
1. Overview
5-24
Setting margin rate
Normally, a barcode whose quiet zone is less than the defined value cannot be read but you can make it readable by
changing the setting values of the right margin rate and the left margin rate.
However, changing the setting values may lead to misreading and affect the reading results. Please assess the influence
carefully before changing the setting values.
Please use this setting as an emergency plan when you have mistakenly printed barcodes without enough quiet zones.
In other cases, it is recommended that the setting values of the margin rates not be changed.
As an example, here is an explanation of a right margin rate.
Right margin
(Quiet zone)
Black background
(blot, etc.)
(1) to (4) Right margin rate
(4)
(3)
(2)
(1)
No.
Margin rate setting value
Readability
(1) Normal
Unreadable
(2) 6/7
Unreadable
(3) 5/7
Unreadable
(4) 4/7
Readable
* Barcodes are readable when the setting value of the margin rate is 4/7 or less (3/7, 2/7, 1/7).