2. Installation & wiring
Function
4. Support tool
5. Appendix
1. Overview
3-28
Slave mode
z
Configuration commands
Setting values can be acquired and changed by inputting configuration commands from the host device to the WB1F.
An example of the control command output format is as follows.
Example: To get the setting value of address 0157 "indicator LED (red) illumination time"
z
Request (host device
→
WB1F)
Prefix
Mnemonic
Address
Data type
Suffix
^
g
0157
x
CR
LF
z
Response (WB1F
→
host device)
Normal response
Prefix
Mnemonic
Address
Data type
data
Suffix
^
g
0157
x
1e
CR
LF
Error response
Prefix
Judgment
Suffix
^
NG-ff
CR
LF
Example: To change the setting value of address 0157 "indicator LED (red) illumination time"
Request (host device
→
WB1F)
Prefix
Mnemonic
Address
Data type
data
Suffix
^
s
0157
x
3c
CR
LF
z
Response (WB1F
→
host device)
Normal response
Prefix
Judgment
Suffix
^
OK-00
CR
LF
Error response
Prefix
Judgment
Suffix
^
NG-ff
CR
LF
z
The error response is when a fault occurs such as a mistake in command input.
z
The address range is 0000H-FFFFH. (16 bits, hexadecimal)
z
The data range is 00H-FFH. (8 bits, hexadecimal)
z
Both uppercase and lowercase are supported for the address and data when making a request.
z
By default, the address and data for a response is lowercase. (Can be changed to uppercase)
z
The check digit can be added to the configuration command request and response.
z
For the other settings, refer to
P. 3-36 "3. 5 Configuration item table"
z
The response time for configuration commands is within 10 ms.