2. Installation & wiring
Function
4. Support tool
5. Appendix
1. Overview
3-10
Slave mode
z
Start conditions and stop conditions for reading requests
Barcode reading and reading request
Operation
Reading
operation
Reading timeout
time
Reading
request
Start condition
Stop condition
Single label read
100 ms to 25,500 ms
(Edge-triggered)
Operation button Push the Operation button
z
Reading succeeded
z
Reading timeout time (2 s) elapsed
External trigger
input
External trigger input off
→
on
z
Reading succeeded
z
Reading timeout time elapsed
Control
commands
Start command input
z
Reading succeeded
z
Reading timeout time elapsed
z
Stop command input
Infinity
(Level-triggered)
Operation button
*1
External trigger
input
External trigger input on
(Reading continues while trig-
ger is on)
z
Reading succeeded
z
External trigger input off
Control
commands
Start command input
z
Reading succeeded
z
Stop command input
M u l t i p l e l a b e l
read
sequential output
100 ms to 25,500 ms
(Edge-triggered)
Operation button
*1
External trigger
input
External trigger input off
→
on
z
Reading timeout time elapsed
Control
commands
Start command input
z
Reading timeout time elapsed
z
Stop command input
Infinity
(Level-triggered)
Operation button
*1
External trigger
input
External trigger input on
(Reading continues while trig-
ger is on)
z
External trigger input off
Control
commands
Start command input
z
Stop command input
M u l t i p l e l a b e l
read
Collectively out-
put
100 ms to 25,500 ms
(Edge-triggered)
Operation button
*1
External trigger
input
External trigger input off
→
on
z
Reading timeout time elapsed
Control
commands
Start command input
z
Reading timeout time elapsed
z
Stop command input
Infinity
(Level-triggered)
Operation button
*1
External trigger
input
External trigger input on
(Reading continues while trig-
ger is on)
External trigger input off
Control
commands
Start command input
Stop command input
*1 For the reading operation by the Operation button, the reading timeout time for single label read is forcibly fixed to 2
seconds.
When reading with control commands, after the reading operation completes, the reading request automati-
cally turns off.
Summary of Contents for WB1F Series
Page 1: ...B 1775 6 WB1F Fix Linear CCD Scanner User s Manual...
Page 115: ...B 1775 6 September 2019...
Page 116: ...B 1775 6...