2. Installation & wiring
Function
4. Support tool
5. Appendix
1. Overview
3-30
Setup support mode
z
Detailed procedure using the Operation button
1
When the unit's power supply is on, push the Operation button
for 5 seconds.
The indicator LEDs (green/orange/red) will flash and the unit will
switch to the waiting state for measurement item to be selected in
setup support mode.
If 5 seconds elapse with no operation, the unit returns to
the same operation mode as before you switch.
2
Push the Operation button.
The indicator LED (green) will flash and the unit will switch to the
waiting state for reading rate measurement to be executed.
To execute the measurement of the reading number of times, push
the Operation button.
The indicator LED (orange) will flash and the unit will switch to the
waiting state for measurement of the reading number of times to be
executed.
Each push of the Operation button switches between
the waiting states for reading rate measurement to be
executed and for measurement of the reading number of
times to be executed.
3
The measurement starts when 3 seconds elapses.
4
Push the Operation button to end the measurement.
When ended, the unit returns to the operation mode before the
switch.
5 sec
Indicator LED
Wait for
measurement item
to be selected
(G)
(O)
(R)
Indicator LED
Wait for reading rate
measurement to
be executed
(G)
(O)
(R)
Indicator LED
Wait for measurement
of the reading
number of time
to be executed
(G)
(O)
(R)
Indicator LED
End measurements
(G)
(O)
(R)