2. Installation & wiring
3. Functions
4. Support tool
Appendix
1. Overview
5-6
Control commands list
5. 5 Control commands list
RS-232 Type
USB Type
No.
Name
Control command
Description
Prefix
Mnemonic
Suffix
1 Start barcode reading ^
get
CR
LF
Starts barcode reading.
2 Stop barcode reading ^
stop
CR
LF
Stops barcode reading.
3 Start matching
^
cmp[reference data]
CR
LF
Starts barcode reading and performs matching.
The matching result is output.
Reference data to sequentially input can be added.
Example:
^cmp12345
CR LF
4 OK output off
^
ok0
CR
LF
Stops the OK output.
5 OK output on
^
ok1
CR
LF
Starts the OK output. (Polarity and duration follow the set-
ting values.)
6 NG output off
^
ng0
CR
LF
Stops the NG output.
7 NG output on
^
ng1
CR
LF
Starts the NG output. (Polarity and duration follow the set-
ting values.)
8
PWM output off
(When successful set-
tings)
^
pwma0
CR
LF
Stops the PWM output.
9
PWM output on
(When successful set-
tings)
^
pwma1
CR
LF
Starts the PWM output. (Frequency, duration, and duty fol-
low the setting values.)
10
PWM output off
(When failure settings)
^
pwmb0
CR
LF
Stops the PWM output.
11
PWM output on
(When failure settings)
^
pwmb1
CR
LF
Starts the PWM output. (Frequency, duration, and duty fol-
low the setting values.)
12 Indicator LED (red) off ^
leda0
CR
LF
Sets the indicator LED (red) to the off state.
13 Indicator LED (red) on ^
leda1
CR
LF
Sets the indicator LED (red) to the on state. (Display pattern
and illumination time follow the setting values.)
14
Indicator LED (orange)
off
^
ledb0
CR
LF
Sets the indicator LED (orange) to the off state.
15
Indicator LED (orange)
on
^
ledb1
CR
LF
Sets the indicator LED (orange) to the on state. (Display
pattern and illumination time follow the setting values.)
16
Indicator LED (green)
off
^
ledc0
CR
LF
Sets the indicator LED (green) to the off state.
17
Indicator LED (green)
on
^
ledc1
CR
LF
Sets the indicator LED (green) to the on state. (Display pat-
tern and illumination time follow the setting values.)
18
Switch to setup sup-
port mode
(Reading rate)
^
sup0
CR
LF
Switches to setup support mode and starts the setup sup-
port function reading rate measurement.
19
Switch to setup sup-
port mode
(Reading count)
^
sup1
CR
LF
Switches to setup support mode and starts the measure-
ment of the reading number of times with setup support
function.
20 Switch to slave mode ^
slave
CR
LF
Switches to slave mode.
21
Switch to maintenance
mode
^
mainte
CR
LF
Switches to maintenance mode.