![Ideal Boilers isar m30100 Installation And Servicing Download Page 6](http://html.mh-extra.com/html/ideal-boilers/isar-m30100/isar-m30100_installation-and-servicing_617000006.webp)
6
isar -
Installation and Servicing
GENERAL
Ecl 6064
CH Flow
DHW Outlet
Condensate Drain
Gas Control
CH Return
Centre
line of
boiler
63
43
49
49
57
66
DHW Inlet
390 (15
3/8
")
Flue
terminal
278 (11")
5 (
1/4
")
100 (4")
*
400 (15
3/4
")
5 (
1/4
")
165
(6
1/2
")
Inset: Water Connections and Gas Connection
See inset
CLEARANCES
BOILER DIMENSIONS
687
(27")
2
BOILER DIMENSIONS, SERVICES & CLEARANCES
all dimensions in mm (in)
The boiler connections are made on the boiler piping frame.
Refer to Frames 24-26.
The following minimum clearances must be maintained for
operation and servicing.
Additional space will be required for installation, depending
upon site conditions.
Side and Rear Flue
a
Provided that the flue hole is cut accurately, e.g. with a core
drill, the flue can be installed from inside the building where
Front clearance
The minimum front clearance when built in to a cupboard is
5mm (1/4") from the cupboard door but 450mm (17 3/4")
overall clearance is still required, with the cupboard door open,
to allow for servicing.
*
Bottom clearance
Bottom clearance after installation can be reduced to 5mm.
However, 100mm must be available for servicing.
wall thicknesses do not exceed 600mm (24"). Where the
space into which the boiler is going to be installed is less
than the length of flue required the flue must be fitted from
the outside.
Installation from inside ONLY
b. If a core boring tool is to be used inside the building the
space in which the boiler is to be installed must be at least
wide enough to accommodate the tool.
REAR FLUE ONLY
MIN. Top clearance required = 145 mm (5
3/4
")
SIDE FLUE ONLY
Horizontal length of flue
Top clearance
from centre line of boiler
required (MIN.)
to outside wall
Dim. A
0.5 m
160 mm
(6
5/16
")
1.0 m
170 mm
(6
11/16
)
1.5 m
185 mm
(7 1
/4
")
2.0 m
200 mm
(
7 7/8
")
2.5 m
210 mm
(8 1
/4
")
3.0 m
225 mm
(8
7/8
")
3.5 m
265 mm
(9
1/4
")
3.5 m
250 mm
(10
5/8
")
4.5 m
260 mm
(10
1/4
")
5.0 m
275 mm
(10
13/16
")
5.5 m
290 mm
(11
3/8
")
6.0 m
300 mm
(11
13/16
")
Summary of Contents for isar m30100
Page 1: ......