17
INSTALLATION
isar -
Installation and Servicing
FLUE OUTLET
1. A
maximum of 6 extension ducts (one suitably
cut) plus the standard flue duct may be used
together.
2. Flue extensions of greater length than 1m (39")
should be supported with the bracket provided,
suitably adjusted. Refer to Frames 18 and 23.
19 FLUE EXTENSION DUCTS - continued
1. Remove the cardboard support aid from the flue and place
safely to one side.
2. Fit the inner flue extension duct onto the inner flue duct.
3. Fit the outer flue extension duct onto the outer air duct.
4. Using the clamp provided clamp the flue lengths together.
5. Repeat steps 1-4 if a second flue extension is required.
6. Measure and mark the flue length required onto the flue,
measuring from the ring near the terminal.
7. To ensure a square cut, mark the flue all the way round.
8. Cut to length using the cardboard support aid.
9. Remove the cardboard and deburr the metal edges.
20 FITTING THE KIT
18
FLUE EXTENSION DUCTS - For flue lengths greater than 650mm
Pack D Flue extension duct kit contents
Note.
Side flue shown
General arrangement
Flue duct support
Flue support cutting aid
(shown folded up)
Wall plugs - 4 off
Extension duct & clamp
1.0m (39") long
No. 10 x2" wood screw - 4 off
Ecl 1244
Ecl 6085
Boiler
Standard flue
Terminal grille
Flue length
Extension flue
Use a maximum of 6m extended flue ONLY
Measure from
this
RING
2
3
Ecl 2540
Summary of Contents for isar m30100
Page 1: ......