43
SERVICING
isar -
Installation and Servicing
67 SAFETY RELIEF VALVE REPLACEMENT
1. Refer to Frame 50.
2. Remove the casing front andbottom panels. Refer to
Frames 42 & 43.
3. Drain the boiler. Refer to Frame 69.
4. Remove the discharge pipe.
5. Remove the 4 screws retaining the rear support plate and
withdraw the plate.
Note.
The M4 screws fit the casing and the self -tapping
screws fit the plastic pump and valve housings, as
shown.
6. Withdraw the securing pin.
68 AUTOMATIC AIR VENT REPLACEMENT
1. Refer to Frame 50.
2. Remove the boiler front and sealing panels. Refer to
Frames 42 & 43.
3. Drain the boiler. Refer to Frame 69.
4. Unscrew the air vent from the extension pipe on the
boiler boss.
5. Fit the new air vent, complete with 'O' ring provided,
and reassemble in reverse order.
Note.
In the event that the extension pipe is removed at
the same time as the air vent, remove it from the
air vent and refit it into the heat exchanger before
fitting the new air vent, ensuring that its ‘O’ ring
seal is in place.
IMPORTANT.
Ensure that the vent cap (A) is loose.
6. Refill the boiler. Refer to Frame 29.
7. Check the operation of the boiler. Refer to Frame 50.
7. Remove the safety valve.
8. Fit the new safety valve and refit the securing pin.
9. Reassemble in reverse order, ensuring correct location
of screws in the support plate and that tabs on the
pump and valve housings engage in slots.
10. Reconnect the discharge pipe.
11. Refill the boiler. Refer to Frame 29.
12. Check operation of the boiler. Refer to Frame 50.
Support plate
M4 screw
2012
M4 screw
Self tapper
screw
Discharge pipe
Safety relief valve
Securing pin
2039
Ecl 2098
Air vent
Vent cap (A)
SER
VICING
Summary of Contents for isar m30100
Page 1: ......