59 GAS CONTROL VALVE REPLACEMENT
1. Refer to Frame 50.
2. Remove the casing front & bottom panel.
Refer to Frames 42 & 43.
3. Swing the control box down into the servicing position.
Refer to Frame 44.
4. Unplug the electrical lead from the gas control valve and
disconnect the earth wire.
5. Remove the sensing tube from the gas control valve.
6. Undo the gas inlet pipe union at the gas
service cock.
7. Undo the union nut on the outlet of the gas
control valve.
8. Slacken the screw securing the valve
mounting bracket and withdraw the valve,
complete with bracket and inlet pipe.
9. Transfer the mounting bracket and gas inlet pipe to the
new gas control valve.
10. Fit the new gas control valve, ensuring that any seals
showing damage or deterioration are replaced.
Reassemble in reverse order.
11. Ensure the sensing tube is correctly replaced and not
kinked or blocked in any way.
12. Check operation of the boiler. Refer to Frame 50.
60
DIVERTER VALVE ACTUATOR REPLACEMENT
1. Refer to Frame 50.
2. Remove the casing front & bottom panel.
Refer to Frames 42 & 43.
3. Squeeze the tab and unplug the electrical lead
from the valve actuator.
4. Rotate the actuator anticlockwise and pull
forward to remove.
5. Fit the new actuator and reassemble in reverse
order.
6. Check operation of the boiler. Refer to Frame 50.