Page 41 -
Tunnel Master® Jr. User Manual
Chapter 4: Wash Configuration
Output Settings
Follow these procedures to set or change the settings for the Outputs in the Tunnel Master® Jr.
Controller software.
Step
Action
Screen Displays
1
Press the MENU button from the
main screen display.
[1] Bump Shift
[4] View Counts
[2] Wet Down Wash
[5] Print Reports
[3] Configure Wash
2
Press the number 3 key to select the
Configure Wash menu option.
[1] Services
[4] Wash Settings
[2] Outputs
[5] Set Date Time
[3] Output Lists [6] Set Password
3
Press the number 2 key to select the
Outputs menu option.
Output _ _
Name _ _ _ _ _ _ _ _ _ _ Start _ _ Type _ Part _ _
Flash _
Extend _ _ _ _ Look _ _ _ Wet _ Panic _ - _ _
F1=PREV F2=NEXT F3=ERASE F4=SAVE
4
From the numeric keypad, type the
desired number for the output.
NOTE:
Review button functions on
page 31.
Service 01 Name Price
Type Rate
F1=PREV F2=NEXT F3=ERASE F4=SAVE
5
Press the
ENT
button on the display
keypad to advance to the next
setting.
Output 01 Name
Start _ _ Type _ Part _ _ Flash _
Extend _ _ _ _ Look _ _ _ Wet _ Panic _ - _ _
F1=PREV F2=NEXT F3=ERASE F4=SAVE
6
From the numeric buttons, type the
number of the Output.
Output 01 Name Roller
Start _ _ Type _ Part _ _ Flash _
Extend _ _ _ _ Look _ _ _ Wet _ Panic _ - _ _
F1=PREV F2=NEXT F3=ERASE F4=SAVE
7
Press the
ENT
button on the display
pad to advance to the next setting.
Output 01 Name Roller
Start _ _ Type _ Part _ _ Flash _
Extend _ _ _ _ Look _ _ _ Wet _ Panic _ - _ _
F1=PREV F2=NEXT F3=ERASE F4=SAVE
8
Using the numeric buttons enter
the Start time in inches or pulses
depending on the wash setting
selection.
Output 01 Name Roller
Start 0084 Type _ Part _ _ Flash _
Extend _ _ _ _ Look _ _ _ Wet _ Panic _ - _ _
F1=PREV F2=NEXT F3=ERASE F4=SAVE