Tunnel Master® Jr. User Manual
- Page 38
Chapter 4: Wash Configuration
Step
Action
Screen Displays
4
Using the numeric keypad, press the
0
key to select
Y
for Yes or press the
0
key again for
N
for No.
NOTE:
Review Tunnel Master Jr. display and
keypad function buttons. See “Tunnel Master Jr.
Display and Keypad” on page 30.
EqptMeasurementInInches?Y_ _ _ _ _ _
F1=PREV F2=NEXT F3=RESET F4=SAVE
5
From the numeric keypad, press the
F4
button to
accept and save the entry.
EqptMeasurementInInches?Y_ _ _ _ _ _
F1=PREV F2=NEXT F3=RESET F4=SAVE
6
Press the
F2
button to advance to the next setting
to enter.
PulseLength _ _ _ _ _ _ _ _ _ _
F1=PREV F2=NEXT F3=RESET F4=SAVE
7
Repeat steps 4 – 6 until all settings have been
programmed.
MaxCarLength _ _ _ _ _ _ _ _ _ _
F1=PREV F2=NEXT F3=RESET F4=SAVE
8
From the main screen display, press the
MENU
button to return to the previous menu screen.
[1] Services
[4] Wash Settings
[2] Outputs
[5] Set Date Time
[3] Outputs Lists [6] Set Password
Table 4-7.
Configure Wash Settings
About Countdown Times
Set the
Wet Down Period
in the panel to the exact wet down time (e.g., 100). This is the amount of time you
want the actual wet down relays to fire and apply water to the equipment.
For example, the
Wet Down Period
is set to 100, the equipment may only get 90 seconds of water (100
seconds minus the 10 seconds required to sound the horn). The wet down will end when the
Tunnel Master® Jr. counts down to zero.
Outputs
The Outputs menu option is where the user will initially setup and later, as needed, edit the wash relays that
activate the various wash equipment. The basic Tunnel Master® Jr. relay box allows for up to 24 outputs. There
is an option to add an additional relay box that will provide for an additional 24 outputs plus a smart relaly for
a total maximum of 72 outputs. The available Outputs menu items and a brief description of their functions
are listed in the following table.
Menu
Function
Output
Enter the relay number corresponding to the relay switch on the outside of the relay box. They
are numbered 1-12 down the left side and 13-24 down the right side.
Name
The name of the specific equipment controlled by this relay. For example, soap foamer.
Start
Enter the number of pulses or inches, depending on the setup choice in Wash Settings, for how
far past the gate switch (electric eye) the piece of equipment should turn on.
Summary of Contents for Tunnel Master Jr