NAV6
plus
NAVTEX System User Guide
67
Fault
Possible cause
ERR on status line
(communications error)
•
No power to Sensor
•
No communications to Sensor
Check connections to sensor. Check for 12V
between YELLOW wire and its BLACK pair
•
Display Mode set to “Slave”
Always set the ‘Display Mode’ to “Master” in
single display systems.
•
Two or more master displays connected
to a sensor
Set the ‘Display Mode’ on one display to
master and set all other displays to slave
No GPS indicator on
status line
No GPS data on NMEA input.
Check the NMEA data connections.
Check that the GPS unit is switched on.
Check that the GPS unit is set to output
compatible NMEA sentences
.
Software Upgrade
Software Upgrade
Software Upgrade
Software Upgrade
The NAV6
plus
has FLASH memory based software. This allows the
NAV6
plus
to be upgraded when new software releases are developed.
Please check our website
www.icselectronics.co.uk
for information on
new releases.
Input Fuse
Input Fuse
Input Fuse
Input Fuse
The NAV6
plus
has a built-in re-settable fuse on its 12V input. This fuse
will trip if the unit due to a fault condition draws excessive currents.
Power must be disconnected from the unit for 10 seconds in order for
the fuse to reset.
Sensor Output Fuse
Sensor Output Fuse
Sensor Output Fuse
Sensor Output Fuse
The NAV6
plus
has a built-in re-settable fuse on its sensor output power
connector. This fuse will trip if a fault condition on the sensor unit draws
excessive currents. The sensor unit power must be disconnected for 10
seconds in order for the fuse to reset.