NAV6
plus
NAVTEX System User Guide
87
•
Place the Positive meter probe on YELLOW (
WHITE of pair ONE
twisted with BLACK
). A correct reading would be greater than 1Meg
ohm
•
Move Positive meter probe to BLACK (
of pair ONE)
. A correct
reading would be less than 10 ohm
•
Move the Positive meter probe to
WHITE of pair TWO (twisted with
BLACK
). A correct reading would be approximately 16000 to 18000
ohm
•
Move the Positive meter probe to BLACK of pair TWO. A correct
reading would be approximately 16000 to 18000 ohm
Sensor current consumption check
Sensor current consumption check
Sensor current consumption check
Sensor current consumption check
All sensor types,
•
Set Digital Test Meter to DC 200mA range
•
Power up the NAV6
•
Lift the yellow (or YELLOW with BLACK band), Note, ‘ERR’ will
display if sensor was previously working
•
Insert Test Meter in line, (‘ERR’ will clear), read DC mV on test
meter. A correct reading would be between 60 and 80mA
Sensor voltage check
Sensor voltage check
Sensor voltage check
Sensor voltage check
All sensor types,
•
Set Digital Test Meter to 20Volt DC range
•
Power up the NAV6
•
Measure voltage across the YELLOW and BLACK pair. A
measurement in the range ‘10.2 to 15 volts’ is correct
Summary of Contents for Nav6plus